As per IS 456:2000 provisions for two-way slabs with continuous edges, the longitudinal steel reinforcement to be provided in the edge strip is based on
D
Step-by-Step Solution
Insight: IS 456:2000 explicitly mandates that the reinforcement in the edge strip of a two-way slab must be at least equal to the minimum shrinkage and temperature reinforcement prescribed for slabs.
Exam route:
- Recall IS 456:2000 Clause 31.2.2 regarding edge strips in two-way slabs.
- The clause states that reinforcement in an edge strip shall be at least equal to the minimum prescribed in Clause 26.5.2.1.
- Clause 26.5.2.1 defines the "Minimum area of reinforcement" (prescribed minimum cross-sectional area of longitudinal steel for slabs).
- Match this with Option D.
Learning route:
In two-way slabs, the slab is divided into middle strips and edge strips. The main reinforcement is calculated for the middle strips based on the design moments.
However, at the edges, torsional moments and negative moments can develop, especially if the edges are not fully restrained. To control cracking and provide adequate ductility, IS 456:2000 Clause 31.2.2 specifies detailing rules for the edge strip.
The code states: "The reinforcement in an edge strip shall be at least equal to the minimum prescribed in 26.5.2.1."
Clause 26.5.2.1 provides the minimum area of longitudinal reinforcement for slabs, which is 0.15% of the gross cross-sectional area for Fe 250 steel, and 0.12% for Fe 415 or Fe 500 steel.
Therefore, the longitudinal steel in the edge strip is not based on a calculated bending moment (Option A), nor is it a fraction of the middle strip steel in either direction (Options B and C). It is strictly based on the prescribed minimum cross-sectional area of longitudinal steel for slabs.